Model No.: SA2100 Brand: Suin Place of Origin: China
Specifications

Power Quality Analyzer 

SA2100

SA2100 Power Quality Analyzer is the professional potable device to measure and analyze the power system quality, supply the harmonics analysis and power quality data analysis, also provide big memory for the data storage, which is used to make the long term logger measuring to power system.

Brief Introduction

SA2100 Power Quality Analyzer is the professional potable device to measure and analyze the power system quality, supply the harmonics analysis and power quality data analysis, also provide big memory for the data storage, which is used to make the long term logger measuring to power system. The PC software can simply upload the data to PC for full analysis. 

 

Main Features 

Waveform real-time display(4 voltages/4 currents)

Half-period RMS measurement (voltage and current)

Measurement of TRMS currents up to 5000A (sensor dependent)

Measurement, calculation and display of harmonics and interharmonics can be up to 50 times. 

Transient capture

Active power, reactive power, apparent power and energy, shift power factor and true power factor

Three-phase unbalance (voltage and current)

Flicker

Inrush current

Detection and record of Dips& Swells, Voltage Rapid Change, Interruption.

Detect according to EN50160 or grid with user-defined limit

Data storage and screenshots (can be replayed or output to a PC)

Through the LAN interface PC can keep real-time remote communication with the Analyzer, operate the Analyzer and read back measurement data

Built-in 8G memory card

 

image.png


General Characteristics

Display

Screen

Color TFT LCD

Size

5.6 inch

Resolution

320×240

Brightness

Adjustable

Housing

Protection

Protection shield, strong

IP

IP51, accords IEC60529

Interface

USB Host

Download file to PC by U disk for analyze with PC software

LAN

For remote control of the Analyzer and measurement data transmission.

Memory

Flash Memory

128MB

TF Card

Standard 8G

Mechanical

Dimension

262× 173 × 66mm

Weight

1.6kg

Enviroment

Working temperature

0°C~ 40°C

Storage temperature

-20°C~ 60°C

Humidity

90% relative humidity

Power

Adapter input

90~264V

Adapter output

12V  2A

Battery

Rechargeable NI-MH ion    7.2V  3.8Ah

Battery Working Time

undefined  7 hours

Battery Charge Time

4 hours

Standard

Measurement Method

IEC61000-4-30 Class-S

Measurement Performance

IEC61000-4-30 Class-S

Power Quality Monitoring

EN50160

Flicker

IEC61000-4-15

Harmonic

IEC61000-4-7

Electrical Safety

Comply with

IEC61010-1 ,Safety Degree: 600V CAT IV    1000V CAT III

Max. voltage at Voltage Input

600V CAT IV    1000V CAT III

Max. voltage at Current Input

42Vpk

 

Wire Combinations

1Ø+NEUTRAL

Single phase with neutral

1Ø SPLIT PHASE

Split phase

1Ø IT NO NEUTRAL

Single phase system with two phase voltages without neutral

3Ø WYE

3-phase 4-wire system, Y type

3Ø DELTA

3-phase 3-wire system delta (Delta)

3Ø IT

3-phase Y type without neutral

3Ø HIGH LEG

4-wire 3-phase delta system (Delta) with center tapped high leg

3Ø OPEN LEG

Open-delta (Delta) 3-wire system with two transformer windings

2-ELEMENT

3-phase 3-wire system without current sensor on phase L2/B (2 Watt meter method)

2 1/2-ELEMENT

3-phase 4-wire system without voltage sensor on phase L2/B

 

Input

Voltage Input

Input Channels

4 (3 phase  + neutral) DC coupling

Max. Input Voltage

1000Vrms

Range of nominal voltage

50 to 500V

Max pulse peak voltage

6kV

Bandwidth

undefined3kHz

Input Impedance

4MΩ/5pF

Current Input

Numbers of Input

4 (3 phase  + neutral) DC coupling

Type

Clamp Current Sensor with mV output

Input Range

1 to 3000Arms with supplied current clamp

Input Impedance

50kΩ

Bandwidth

undefined3kHz

Sampling System

Resolution

8 channels 16 bits AD

Sampling Rate

20kS/s for each channel, 8 channels sample synchronously

RMS Sampling

5000 points for 10/12 cycles (according to IEC 61000-4-30)

PLL Sync

4096 points for 10/12 cycles (according to IEC61000-4-7)

 

 

Measurement

 


Measurement Range

Resolution

Accuracy

Voltage/Current/Frequency

Vrms(AC+DC)

1 ~ 1000Vrms

0.1Vrms

±0.5% of nominal voltage

Vpk

1 ~ 1400Vpk

0.1Vpk

±0.5% of nominal voltage

V(Crest Factor)

1.0 ~ undefined2.8

0.01

±5%

Arms (AC)

1~ 1000A/3000A/5000A

1A

±1% ± 2A

1~ 100A

0.1A

±1% ± 0.2A

Apk

1 ~ 4000Apk

1A

±1% ± 2A

A(Crest Factor)

1 ~ 10

0.01

±5%

Frequency

42.5 ~ 57.5Hz (50Hz nominal)

0.01Hz

±0.01Hz


51 ~ 69Hz (60Hz nominal)

0.01Hz

±0.01Hz

Dips & Swells

Vrms1/2

0 ~ 200% of nominal voltage

0.1Vrms

±1%

Arms1/2

1 ~ 3000A

1A

±1% ±2A

Threshold levels

Threshold is settable according to nominal voltage percentage
   Detectable events type: Dips, Swells, Interruption, Voltage Rapid Change

Duration

hour-minute-second-microsecond

0.5 period

1 period

Harmonic

Harmonic Number

1 ~ 50



Inter-Harmonic (SA2100)

1 ~ 49



Harmonic Voltage

0.0 ~ 100.0%

0.1%

±0.1% ± nx0.1%

Harmonic Current

0.0 ~ 100.0%

0.1%

±0.1% ± nx0.1%

THD

0.0 ~ 100.0%

0.1%

±2.5%

DC Relative

0.0 ~ 100.0%

0.1%

±0.2%

Frequency

0 ~ 3500Hz

1Hz

1Hz

Phase

-360° ~ 0°

± nx1.5°

Power and Energy

Active Power/Apparent Power/Reactive Power

1.0 ~ 20.00MW

0.1kW

±1.5±10 digits

Energe

0.00kWh ~ 200GWh

10Wh

±1.5±10 digits

Power Factor

0 ~ 1

0.01

±0.03

Flicker (only for SA2100)

Pst(1min),Pst,Plt,PF5

0.00 ~ 20.00

0.01

±5%

Unbalance

Voltage

0.0 ~ 5.0%

0.1%

±0.5%

Current

0.0 ~ 20.0%

0.1%

±1%

Voltage Phase

-360° ~ 0°

±2digits

Current Phase

-360° ~ 0°

±5digits

Voltage Transient (only for SA2100)

Vpk

±6000Vpk

1V

±15%

Vrms

10 ~ 1000Vrms

1V

±2.5%

Min. Test Time

50us

Sampling Rate

20kS/s

Inrush Current (only for SA2100)

Arms(AC+DC)

0~3000Arms

0.1

±1% ± 5digits

Inrush Duration

6s ~ 32min selectable

10ms

±20ms

Logger

Recording

user-defined parameters for 4 phases at the same time

Memory

Data stored in TF card, 8GB

Duration Time

2 hrs to 1 year

Interval

1s to 1 hrs

 

For more quality products, Contact Now!

 

Send your message to this factory
From:
Message:
Enter between 20 to 4,000 characters.
Contact Details

Lisa Liu

Lisa Liu
manager

none.

none.

none.

none.

none.

Give Us a Comment
English 免费注册 手机号登录
简体中文 Join Free Now! Mobile number sign in
English 免费注册 邮箱登录
简体中文 Join Free Now! Email sign in
English 已有账号? 立即登录 使用手机号注册
简体中文 Have an Account? Sign in Register with Mobile Number

创建账户

设置密码

  • 强度
  • 8~20个字符
  • 只能包含字母和数字,区分大小写
  • 必须包含字母和数字

验证手机号码

公司名称

English 已有账号? 立即登录 使用邮箱注册

Create an Account

Password

  • Strength
  • 8-20 characters
  • Only consist of letters, numbers ,case sensitive
  • Must contain letters and numbers

Verify mobile number

Company Name

First Name

Last Name

简体中文 Have an Account? Sign in Register with Email